Welcome to visit Ruijiu Electrical   
Yancheng Ruijiu Electrical Technology Co., Ltd.
 
 
 
 
 
 
 
 
 
 
 
Long-distance remote control motor

1000 m 2 button wireless remote control

 
The remote control with 6F22 (9V) Battery a
 
A transmitter major technical indicators
1, operating voltage: DC9V (6F22 battery one, namely multimeter battery)
2, Working current: ≤ 50mA
3, Operating frequency: 315MHz or 433MHz (433MHz to be made)
4, the encoding type: 2264 chip pad encoding
5, Transmission Distance: 1000 meters line of sight, which is open to non-interference from the theoretical distance, use the short cut will vary according to the different environmental interference, walls and obstacles. Typically about 10% -30% of nominal distance.
6, the encoding type: fixed code
7, vibration resistance: 4.7M (If you need additional numerical oscillation resistor please explain in advance)
8 Dimensions: 135 × 43 × 28mm
 
Typical applications
1, automobile, motorcycle alarm;
2, home burglar alarm;
3, the wireless remote controller is used in conjunction with a wireless receiver, mainly used in electric garage doors, window areas, gates, lifting equipment, gateways, various anti-theft alarm, industrial automation and security industries;
4, industrial automation and control.
 
The main technical parameters of the receiver
(A) technical parameters
 
1, the working voltage: AC220V ± 10%
2, operating temperature: - 10 鈩 - +60 鈩
3, the receiving frequency: 315MHz
4 Receiver sensitivity:-105dB
5, relay contacts rated load current: resistive load ≤ 8A (purely resistive loads such as: incandescent, electric water heaters, rice cookers, etc.), inductive load ≤ 2.5A (such as: water pump, air-conditioning, TV, energy-saving lamps, etc.)
6, output: relay switch signal (two relay output switching signal, namely: independent two normally open / normally closed changeover contact)
7, work: jog, interlocking, self-locking, self-locking way jog all the way (as the jumper position may be, simple and practical)
8, Case Size: 75 × 55 × 30mm
 
(B) access lines and determine the output
 
1, the input to L, and access to FireWire.
2, the input terminal marked N, access to the zero line.
3, the board is labeled 1, 2, a group of three output terminals of the relay corresponding to NC, COM, NO.(Output switching signal);
4, the three plates 4,5,6 marked another relay output terminals, corresponding NC, COM, NO (output switching signal);
5, set the output mode: on-board jumpers JP2 position there, the power forward runs good. After the jumpers (according to the 6,7,8), output state also determined. (Note: The output state is determined before power changed after power jumper, does not change its output function)
6, set the output mode to: jog! 1,2 jumper to end (this short-circuited at both ends), the instantaneous output (Jog); specifically: Press the remote control button, the relay will pull, release the button on the remote control, the relay releases.
7, set the output mode is: self-locking! 3,4 jumper to end (this short-circuited at both ends), output is steady (self-locking); specifically: Click the button on the remote control, the corresponding relay this group, click the button on the remote control, the corresponding This relay is disconnected;
8, set the output mode is: Interlock! Jumper pulled, no; output is: interlock, specifically: Press the A button on the remote control, Group 1 relay, press the B button on the remote control, relay group 2, group 1 relay off open, two relays are presented interlock state. Press the C button, two relays are disconnected.
 
9, the short JP1 1,2, 3,4 shorted, set the output mode to jog all the way, all the way to the self-locking;
Tips: When setting the product output, need to be set before energizing. Invalid change JP2 jumper after power position.
10 For other special features, please contact us.
 
11 Tips:
鈽 This controller allows up to four different coding learning remote control, learning first five after the first failure, and so on
鈽 The controller can be used with fixed code 2260/2262/2264/5211 and other remote uses, vibration resistance is not limited to, 4.7M best. You can also learn codes with 1527/2240 and other remote uses, vibration resistance is not limited to, 330K best.
 
(C) learning the code and clear
 
1, above the line and take a good way to determine the output, you need by learning the code to use the remote control correctly.
2, follow the steps, step by step.
3, the control panel has a touch switch S1, this button is used to study the code and cleared for use.
4, clear: Before learning the code, you need to clear the operation. Specific operation is: Do not put press S1, see LED lit, do not release until the LED blinks to see, OK. Cleanup operation is complete.
5, learning the code: The code is based on a different state to the corresponding output. If the output mode to jog or self-locking, then just use two remote control buttons to control it, so just learning two buttons. If the output is interlocked, then, need to learn three different remote control buttons to control it. Here it is divided into two different ways of learning to look at. Jog learning and self-locking is the same, they are interlocked with different learning styles.
(1): Output to jog and self-locking of learning the code: Press S1, see the LED lit release S1, this time into learning state, complete the following steps within five seconds, press the remote control The first one button (the button after learning to control the first one-way), see the LED flashes two times, and then continue to press the second button on the remote control (the button after learning to control 2-way), see LED flashes four times to go out. Study is completed. If learning is unsuccessful, repeat 4,5, step.
(2): output is interlocked learning code: Press S1, see the LED lit release S1, this time into learning state, complete the following steps within five seconds, press the remote control first (the control button after learning the first road) a button to see the LED flashes, the first two and then press the button (the button after learning to control 2-way) to see the LED blinks three times, and then Press the remote control first three buttons (the button after learning function is off two-way), LED blinks 4 under extinguished. Study is completed. If learning is unsuccessful, repeat 4,5, step.
6, the product is a multi-functional, versatile, because more functions, actions might need to step. Moreover, learning can be repeated cleared.
7, be sure to pay attention to safety, followed by a good line powered board with strong electricity! ! ! After power can not live hand touch pad on the metal part of the operation (except by remote control), the human need to ensure a good ground isolation! Moreover, the input must be leakage protection switch can be used.
 
(D) wiring diagram
 
  銆怬RDER銆   銆怋ACK銆
 
About us | Culture | Products | Order | Contact us | 涓枃鐗銆銆Admin
Copyright(C)2014, Yancheng Ruijiu Electrical Technology Co., Ltd. All Rights Reserved. Supported by ToocleCopyright Notice
 
鐐瑰嚮杩欓噷缁欐垜鍙戞秷鎭
鐐瑰嚮杩欓噷缁欐垜鍙戞秷鎭